Cisco Cisco IP Contact Center Release 4.6.1 发行公告

下载
页码 92
 
Cisco Unified ICM/Contact Center Enterprise & Hosted Editions, Release 7.5, 
 
Hardware and System Software Specification 
 
©2008-2011 Cisco Systems, Inc. 
 
6  
Note: Severe network communication problems are likely when 10/100 Mbps NICs and switch ports are not BOTH 
explicitly set to the capable speed in Full Duplex operation. 
Cisco highly recommends the use of gigabit (1000 Mbps) server network interface cards and gigabit network switches. 
 
 
Storage Hardware 
Cisco  Unified ICM and Unified CC are  I/O  intensive  applications  that handle call routing, process  logging,  and historical 
archiving.  I/O write operation capacity is of particular criticality.  The use of SCSI hard disk drives is the default required 
unless otherwise specified.   Components where Serial or Parallel ATA (Advanced Technology Attachment) drive use is 
acceptable are explicitly identified in the applicable node’s hardware specifications. 
 
Required controllers: 
•  SCSI/SAS 
o
  Ultra160/3 (minimum) 
o
  Ultra320 (recommended) 
o
  SAS 3.0Gb/s (highly recommended)
 
 
•  ATA 
o
 
Serial (recommended) 
o
 
Parallel  
Disk Drives: 
•  SCSI/SAS 
o
 
3.5” Form Factor 
  15,000 RPM for Cisco Unified ICM and Unified CC Loggers, Historical Data Servers and other database 
servers 
  10,000 RPM (minimum) for all other nodes 
o
 
2.5” Form Factor 
  15,000 RPM preferred for database servers (if available) 
  10,000 RPM (standard) for all other nodes 
•  ATA 
o
  7,200 RPM 
Additional Media: 
•  DVD drive (software installation) 
 
Configuration guidelines: 
•  A dedicated on-board or add-in RAID controller must be used with a minimum of 128 MB of battery backed cache. 
•  Increasing the number of physical drives increases the overall fault tolerance of the disk array. 
•  Use controllers with multiple channels connected to discrete drive bays or backplanes. 
Note: 
Multiple controller channels can be of significant advantage when there are multiple drive bays and backplane 
connections.  Each channel of the controller can connect to a separate backplane connection, and arrays split 
between the channels and backplanes can take advantage of the increased throughput as well as increased 
resiliency. 
•  Two channels per external storage enclosure. 
                                                           
3
 Serial Attached SCSI