Cisco Cisco UCS B22 M3 Blade Server 数据表

下载
页码 70
Cisco UCS B420 M3 Blade Server
SUPPLEMENTAL MATERIAL
63
Connectivity using the Cisco UCS 2104XP Fabric Extender
The connectivity options shown in 
 are shown in 
.
Table 33  Supported Adapter
1
 Combinations Using the 2104XP
2
Notes
1. In the server BIOS and on the motherboard, “Adapter 1,” “Adapter 2,” and “Adapter 3” are labeled as 
“mLOM,” “Mezz 1,” and “Mezz 2,” respectively
2. Not all combinations are supported in 2-CPU configurations (see 
)
Adapter Slot 1
Adapter Slot 2
Adapter Slot 3
Total Available Bandwidth
2 x 2104 XP
VIC 1240
Not populated
Not populated
20 Gb
VIC 1240
Not populated
VIC 1280
40 Gb
Not populated
Not populated
VIC 1280
20 Gb
VIC 1240
Not populated
Emulex or QLogic CNA
40 Gb
VIC 1240
Port Expander Card 
Not populated
Network I/O not supported
3
3.
The 2104XP fabric extender is not compatible with any network I/O card installed in adapter slot 2.
Not populated
Not populated
Emulex or QLogic CNA
20 Gb
VIC 1240
Not populated
Cisco UCS Storage 
Accelerator
20 Gb
VIC 1240
Cisco UCS Storage Accelerator
4
4. This combination requires that both Storage Accelerators be identical.
Cisco UCS Storage 
Accelerator
4
20 Gb
Not populated
Cisco UCS Storage Accelerator
VIC 1280
20 Gb
VIC 1240
Port Expander Card 
VIC 1280
Network I/O not supported
3
VIC 1240
Cisco UCS Storage Accelerator
VIC 1280
40 Gb