Crestron cen-tvav 用户手册

下载
页码 52
Ethernet Enabled Programmable TV/AV Controller 
Crestron CEN-TVAV
 
 
RJ11 Modular Cable Pinouts 
PIN
DESCRIPTION
PIN
DESCRIPTION
1
CTS (Clear to Send)
4
TxD (Transmitted Data)
2
GND
5
RTS (Request to Send)
3
RxD (Received Data)
6
Not Connected
 
PC to Control Processor (CEN-TVAV) Cable Specification 
1
2
3
4
5
6
7
8
9
8
7
5
3
2
6
5
4
3
2
1 CTS
GND
RxD
TxD
RTS
n/c
TO PC
COM PORT
TO RS-232
PORT
1
PART #
AWC10152-A
PART #
748047-1
PART #
641337
REAR VIEW OF
CONNECTOR
(9-PIN FEMALE)
 
Special Considerations for Using the RS-232 Port 
for Uploading Programs 
The CEN-TVAV has a single RS-232 port that is used for uploading programs and 
communicating with RS-232 equipment for control purposes. Since the port is 
shared, the operation of the console port is slightly different from standard CNX 
systems that have a dedicated RS-232 console ports. When a program is loaded into 
a CEN-TVAV that uses the TVAVCOM-1 port, the program will initialize but the 
shared port will still be attached to the console. The program will run normally, but 
the TVAVCOM-1 port will effectively be “disconnected” from the system. This is 
done so other configurations (such as uploading SIMPL+ modules, setting the IP 
Table, etc.) can be done. 
After the program is rebooted (using F10 in the Viewport or cycling operating 
power), the shared port is taken over by the TVAVCOM-1 port (if the TVAVCOM-1 
symbol is present in the program) when the SIMPL program initializes. Note that 
SIMPL Windows will not convert the TVAVCOM-1 port if there are no signals or 
data coded in the port, or if the symbol is commented out. When the program 
initializes, the normal TVAV bootup messages will be issued out the TVAVCOM-1 
port, i.e.:  
 TVAV Monitor v5.10.13 - 03/07/00 - interrupt serial i/o 
 512k flash memory, 512k SRAM, segment =F900 
 Press <esc> now to enter debug monitor 
If there is a device hooked up to the TVAVCOM-1 port, the bootup message may be 
treated as false characters and cause device errors. It is possible to set the baud rate 
to DISABLE (pressing F8 while in the Viewport and selecting DISABLE) for the 
console port. This will cause the initial bootup message to not be displayed. In order 
to obtain communications with the CEN-TVAV through the RS-232 port, the 
following methods can be used:  
10  
  Ethernet Enabled Programmable TV/AV Controller: CEN-TVAV 
Operations Guide - DOC. 5720A