Initial Installation
QUALIFIED INSTALLERS ONLY
E
LECTRICAL
 R
EQUIREMENTS
 F
OR
 G
AS
 V
ALVE
 
AND
 O
PTIONAL
 B
LOWER
:
The ENVIRO CARA will operate without electrical power. This model has a millivolt gas control, which 
uses the pilot flame to generate enough electricity to operate the main burners. The appliance when 
equipped with an optional blower must be electrically connected and grounded in accordance with local 
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 
1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI 
/ NFPA 70 in the U.S.
WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding) 
plug for your protection against shock hazard, and must be plugged directly into a properly grounded 
three-prong outlet.  
Figure 34: Gas Control Valve and Optional Thermostat Wiring.
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
Optional
Remote
Control
ON/OFF
Burner Switch
Purple
Thermocouple
Blue
Thermopile
Grey
Inlet
Pressure
Tap
Gas Control
Valve
Manifold
Pressure Tap
Pilot Adjustment
Screw
Optional
Wall Switch
Optional
Thermostat
Table 9: Recommended Thermostat
 Wire Size.
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
CAUTION:  Label  all  wires  prior 
to  disconnection  when  servicing 
controls.  Wiring  errors  can  cause 
improper  and  dangerous  operation. 
Verify  proper  operation  after 
servicing.
Figure 35: Wiring Diagram for Electric Fan.
DO NOT cut or remove the grounding prong 
from this plug.
ELECTRICAL INFORMATION:
Canadian Installations
The  venting  system  must  be  installed  in 
accordance  with  the  current  CSA  B149 
installation  code  and/or  local  codes  having 
jurisdiction.
U.S.A. Installations
The  venting  system  must  be  installed  in 
accordance  with  the  current  National  Fuel 
Gas  Code,  ANSI  Z223.1,  and/or  local  codes 
having jurisdiction.
Rheostat
Snap Disk N/O
Black
Green/White
Black
White
Fan
Power
Cord
Black
Black
Black
Green/Yellow