Figure 36: Optional Blower (Fan) Installation.
1.  Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is 
noticed call your dealer, distributor or courier company and have components replaced.
2.   Remove  the  side  panel  by  pulling  the  panel  up,  slide  the  panel  out  of  the  bottom  slots,  and  set 
aside.
3.  Install the temperature sensor into the holder. 
 
IMPORTANT: The temperature sensor must be in contact with the firebox.
4.  Open the pedestal door and remove the four (4) T-20 screws holding the Control Panel in place.
5.  Fit the Fan Unit into the cabinet being careful to work around the gas and pilot lines. The fan will 
fit up behind the gas valve. With an extension driver, fasten the Fan Unit in place with four (4) T-20 
screws provided.
6.   Install the Fan Controller into the provision in the Control Panel. 
7.   Install the Strain Relief plate into the stove back by fitting the tab on the plate into the stove back 
and secure the plate with a T-20 screw provided.
8.   Plug  in  all  the  electrical  connections  as  indicated  in  Figure  35.  This  includes  the  Fan  Controller, 
Temperature sensor and Fan Unit.
9.   Using the provided T-20 screw, located on the right mount below and behind the Temperature Sensor, 
fasten the wire tie supplied. With the wire tie capture the fan wires including the temperature switch 
wires, this will secure the wires and route them away from hot surfaces and out of the way of the fan 
blades 
10. Re-install the Control Panel and Side Panel.
11. Plug the fan assembly into the wall outlet and turn the unit on to ensure fan operation.
Initial Installation
I
NSTALLATION
 
OF
 O
PTIONAL
 B
LOWER
:
22