Removal and Replacement Procedures 
6.  Reference the LEDs on the top of the memory board to make sure that the memory is 
functioning properly. The following table describes what the LEDs look like for each 
memory configuration when the DIMMs and memory board are functioning properly. For 
more information on LEDs, refer to Chapter 4, “Connectors, LEDs, and Switches.” 
 
 
Table 2-7:  Memory LED States on a Properly Functioning Memory Board 
Memory Configuration 
LED 
Advanced ECC 
(Standard 
Memory) 
Online Spare 
Memory 
Single-Board 
Mirrored 
Memory 
Hot-Plug  
Mirrored  
Memory 
Memory Status 
Green 
Green 
Green 
Green 
DIMMs 1-8, if 
populated 
Green 
Green 
Green 
Green 
Online Spare 
Status 
Off 
Green 
Off 
Off 
Mirroring Status 
Off 
Off 
Green 
Green 
Online Spare 
Text*  
Off 
Green 
Off 
Off 
Ready to Hot 
Plug 
Off 
Off 
Off 
Green 
*If two memory boards are installed, the online spare text is only illuminated for the memory board in 
slot 1. 
NOTE:
  When the server is configured for online spare memory, Bank D is the online spare bank. 
7.  If any of the LEDs are illuminated solid amber, indicating a failed DIMM, or blinking 
amber, indicating improper DIMM configuration, refer to the HP Servers 
Troubleshooting Guide
 on the Documentation CD for instructions. 
8.  Close the hot-plug door. 
9.  Close the front bezel door (tower model only). 
HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide 