Information for Users in the U. S.
For units set at 115 V : 
Use a UL Listed Cord Set consisting of a minimum 18 AWG, Type SVT or SJT three conductor cord a 
maximum of 15-feet long and a parallel blade, grounding type attachment plug rated 15 A, 125 V. 
For units set at 230 V: 
Use a UL Listed Cord Set consisting of a minimum 18 AWG, Type SVT or SJT three conductor cord a 
maximum of 15-feet long and a tandem blade, grounding type attachment plug rated 15 A, 250 V. 
Information for Users outside the U.S.
For units set at 230 V: 
Use a Cord Set rated minimum 5 A, 250 V ( for units set at 230V ) or 10A, 125V (for units set at 115V). The 
Cord Set should have the appropriate safety approvals for the country in which the equipment will be 
installed.
 