Mounting guidelines
LINAK
®
 linear actuators are quickly 
and easily mounted by slipping pins 
through the holes on each end of 
the units and into brackets on the 
machine frame and the load. 
The mounting pins must be parallel 
to each other as shown in Figure 1. 
Pins, which are not parallel to each 
other, may cause the actuator to 
bind and be damaged.
The load should act along the 
stroke axis of the actuator since 
off centre loads may cause 
bending and lead to premature 
failure. See Figure 2.
Make sure the mounting pins are 
supported in both ends. Failure to 
do so could shorten the life of the 
actuator. Cantilever mounts are 
unacceptable.
Figure 1
Figure 2
X
X
RIGHT
WRONG
WRONG
Warning!
If the actuator is used for pull in an application where personal injury 
can occur, the following is valid:
It is the application manufacturer’s responsibility to incorporate a 
suitable safety arrangement, which will prevent personal injury from 
occurring, if the actuator should fail.
Warning!
LINAK’s actuators are not constructed for use within the following 
fields:
•  Offshore installations
•  Aeroplanes and other aircraft
•  Explosive environments
•  Nuclear power generation
10