Linak techline la36 用户手册

下载
页码 20
11
The cover over the Allen key socket must be unscrewed before the Allen 
key can be inserted and the Hand Crank operated.
Hand Crank Torque: 6 - 8 Nm ( 2600 N – 6800 N load )
Piston Rod movement per turn 
Gear A = 10.5 mm
Gear B =   6.0 mm
Gear C =   4.0 mm
Application hints
The actuator is weather proof for use in outdoor applications. The actuator 
can be washed down with a high pressure washer, but it should not be used 
under water.
Optionally the actuator is overload protected with a slip clutch. The clutch will 
slip when the load exceeds approx. 1.2 - 1.4 times the actuators rating.
The duty cycle at max. load is 20% on time. This means if the actuator 
runs continuously for 20 seconds it must remain off for 80 seconds before 
operating again.
The manual hand crank can be used in the case of power failure.
Note: The power supply has to be disconnected during manual 
operation.
6 mm Allen key
Manual hand crank