Hitachi travelstar hds723020bla642 用户手册

下载
页码 173
7K200 SATA OEM Specification 
132/173 
 
14.33  Sense Condition (F0h : vendor specific)   
Command Block Output Registers 
  Command Block Input Registers 
Register 
7 6 5 4 3 2 1 0  Register 
7 6 5 4 3 2 1 0
Data 
- - - - -
-
-
-  Data 
- - - - - -
-
-
Feature 
0 0 0 0 0 0 0 1  Error 
...See 
Below... 
Sector 
Count 
- - - - -
-
-
-  Sector 
Count 
V V V V V V V V
LBA 
Low 
- - - - -
-
-
-  LBA 
Low 
- - - - - -
- N
LBA 
Mid 
- - - - -
-
-
-  LBA 
Mid 
- - - - - -
-
-
LBA 
High 
- - - - -
-
-
-  LBA 
High 
- - - - - -
-
-
Device 
- - - - -
-
-
-  Device 
- - - - - -
-
-
Command 
1 1 1 1 0 0 0 0  Status 
...See 
Below... 
 
Error Register 
 
Status Register 
7 6 5 4 3 2 1 0 
 7 6 5 4 3 2 1 0 
CRC UNC  0 
IDN 
0  ABT  T0N
AM
 BSY RDY
DF DSC DRQ 
COR IDX
ERR
0  0  0 V 0 V 0  0 
 V V V -  V  -  0 V 
Table 103 Sense Condition Command (F0h)   
The Sense Condition command is used to sense temperature in a device.   
This command is executable without spinning up even if a device is started with No Spin Up option.   
If this command is issued at the temperature out of range which is specified for operating condition, 
the error might be returned with IDN bit 1.   
Output Parameters To The Device 
Feature 
The Feature register must be set to 01h. All other value are rejected with 
setting ABORT bit in status register. 
Input Parameters From The Device 
Sector Count 
The Sector Count register contains result value. 
 
Value Description 
 
00h 
Temperature is equal to or lower than -20 degC 
 
01h-FEh 
Temperature is (Value / 2 - 20) deg C 
 
FFh 
Temperature is higher than 107 degC 
Not recommendable condition for start up. If over stressed condition is 
detected, this bit will be set to one.