Juniper Networks T1600 用户手册

下载
页码 113
Duplex SC/PC connector (Rx and Tx); single-mode fiber
Optical interface support—See Table 19 on page 35
Cables and connectors
One tricolor per port:
Off—Not enabled
Green—Online with no alarms or failures
Amber—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
LEDs
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE),
far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Frame error
Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Yellow alarm bit (X-bit) disagreements
Alarms, errors, and
events
Layer 2 per-queue and per-channel packet and byte counters
Instrumentation
(counters)
Table 19:  Optical Interface Support for Channelized OC12 IQ PICs
Intermediate Reach (IR)
Parameter
Single-mode
Optical interface
Telcordia GR-253
Standard
9.3 miles/15 km
Maximum distance
1274 through 1356 nm
Transmitter wavelength
–15 through –8 dBm
Average launch power
–8 dBm
Receiver saturation
–28 dBm
Receiver sensitivity
Channelized OC12 IQ PIC
35
Channelized OC12 IQ PIC