National Instruments 653X 用户手册

下载
页码 147
Chapter 3
Timing Diagrams
3-26
ni.com
 
Figure 3-22.  Trailing Edge Input Timing Diagram
Note
When REQ-edge latching is enabled (default), the REQ edge determines when data 
will be latched. Input data valid needs to be held t
r*di 
after the trailing edge of REQ occurs. 
When REQ-edge latching is disabled, input data valid needs to be held t
adi
 after the active 
going edge of the ACK signal occurs.
Parameter
Description
Minimum
Maximum
Input Parameters
t
rr*
REQ pulse width
75
t
r*r
REQ inactive duration
75
t
dir*
Input data setup to REQ inactive
(with REQ-edge latching)
0
t
r*di
Input data hold from REQ inactive
(with REQ-edge latching)
10
t
dir
Input data setup to REQ
(with REQ-edge latching disabled)
0
t
adi
Input data hold from ACK
(with REQ-edge latching disabled)
0
Output Parameters
t
aa*
ACK pulse width
225
1
275
2
t
a*r*
ACK inactive to next REQ inactive
0
1
 
t
aa*
 (min.)
 
= 225 + programmable delay
2
 t
aa*
(max) = 275 + programmable delay
REQ
Input Data Valid
(REQ-edge
latching)
Input Data Valid
(REQ-edge
latching disabled)
t
dir*
t
r*r
t
dir
t
aa*
t
a*r*
t
rr*
t
r*di
ACK
t
adi
ACK and REQ are shown as active high