National Instruments 1000DC 用户手册

下载
页码 42
Chapter 2
Configuring and Installing the SCXI Chassis
2-14
ni.com
Complete the following steps to check or replace fuses:
1.
Remove the appropriate fan and filter from the rear of the chassis by 
following the instructions in th
 section
Make sure to switch the power off and remove the power cord.
2.
The fuse marked with a copper + on the backplane is for the positive 
analog supply, and the fuse marked with a copper – is for the negative 
analog supply. To check whether a fuse is blown, connect an ohmmeter 
across the leads. If the reading is not approximately 0 
Ω, replace 
the fuse.
3.
Using a pair of needle-nose pliers, carefully extract the fuse.
4.
Take a new fuse and bend its leads so the component is 12.7 mm 
(0.5 in.) long, the dimension between the fuse sockets, and clip the 
leads to a length of 6.4 mm (0.25 in.).
5.
Using the needle-nose pliers, insert the fuse into the socket holes.
6.
Repeat, if necessary, for the other fuse.
7.
Check the fan filter and, if it is dirty, clean it as described in the 
 section.
8.
Reinstall the fan and filter.
Replacing the Fuses on the SCXI-1000DC
There are two fuses located on the rear panel of the SCXI-1000DC. The 
input power fuse (F1) is a 6.3 A, 5 
× 20 mm time-lag fuse. The internal 
+5 VDC supply is fused by a 3.15 A, 5 
× 20 mm time-lag fuse (F2).
Replacing the Power Entry Fuse and +5 VDC Fuse
Caution
For continued protection against fire, replace fuses only with fuses of the same 
type and rating.
Complete the following steps to replace the rear panel fuses:
1.
Power off the chassis.
2.
Remove the power cord from power entry connector J1.
3.
Turn the fuse holder counter-clockwise with a screwdriver and pull out 
the fuse holder to expose the fuse in the housing.
4.
Remove the fuse.
5.
Install the new fuse.