National Instruments 1000DC 用户手册

下载
页码 42
Chapter 2
Configuring and Installing the SCXI Chassis
2-12
ni.com
Selecting the Voltage
Complete the following steps to select a voltage:
1.
Power off the chassis.
2.
Remove the power cord from the power entry module.
3.
Using a flathead screwdriver, pry the door to the tumbler open from 
the top.
4.
Remove the voltage tumbler.
5.
Rotate the tumbler to the appropriate voltage and reinsert it into the 
power entry module.
6.
Close the door.
7.
Check to make sure that the voltage showing on the selection tumbler 
is correct.
8.
Reinsert the power cord.
SCXI-1001
100 V Japan
1
2.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
120 V
1
1.6 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
220 V Swiss
1
1.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
240 V Australia
1
1.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
240 V Europe
1
1.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
240 V North American
1
1.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
240 V U.K.
1
1.0 A 250 5 mm 
× 
20 mm SLO-BLO
2
4 A 125 V LittleFuse 
R251 01.5 TI
Table 2-4.  SCXI-1000/1001 Voltage Selection and Fuse Ratings by Region (Continued)
SCXI 
Chassis 
Type
Region/Voltage
Main 
Power Fuse 
Quantity
Main Power
Fuse Type
Backplane 
Fuse 
Quantity
Backplane
Fuse Type