Intel netstructure mpcbl0001 用户手册
![Intel](https://files.manualsbrain.com/attachments/5a71b1e7f60391972dadeef20435931cbf4621a5/common/fit/150/50/86c99b5f14aeb2708e9a9e1b5305af4ccf882c1af0155dad25413c2ed84e/brand_logo.png)
46
Technical Product Specification
Order #273817
Intel NetStructure
®
MPCBL0001 High Performance Single Board Computer
Contents
3.4
E-Keying
E-Keying has been defined in the PICMG 3.0 Specification to prevent board damage, prevent
misoperation, and verify fabric compatibility. The FRU data contains the board point-to-point
connectivity record as described in Section 3.7.2.3 of the PICMG 3.0 Specification.
misoperation, and verify fabric compatibility. The FRU data contains the board point-to-point
connectivity record as described in Section 3.7.2.3 of the PICMG 3.0 Specification.
Upon management power-on, the firmware sets the Fibre Channel ports to front panel by default.
When the board enters M3 power state, the shelf manager reads in the board point-to-point
connectivity record from FRU and determines whether the board can enable the Fibre Channel
ports to the back plane. Set/Get Port State IPMI commands defined by the PICMG 3.0
Specification are used for either granting or rejecting the E-keys.
When the board enters M3 power state, the shelf manager reads in the board point-to-point
connectivity record from FRU and determines whether the board can enable the Fibre Channel
ports to the back plane. Set/Get Port State IPMI commands defined by the PICMG 3.0
Specification are used for either granting or rejecting the E-keys.
If user Fibre Channel selection is to the front, the firmware maintains the Fibre Channel ports to the
front panel regardless of the shelf manager’s granting or rejecting of E-keys for the board.
front panel regardless of the shelf manager’s granting or rejecting of E-keys for the board.
, describes the:
•
Connections to base and fabric interfaces on the MPCBL0001 board for E-keying purposes.
•
Link descriptor list for the two Gigabit Ethernet channels connected to the base interface and
the two Fibre Channels on the fabric interface.
the two Fibre Channels on the fabric interface.
NOTE:
Fibre Channel E-keying is only applicable to MPCBL0001FXX products.
3.5
IPMC Firmware Code
IPMC firmware code is organized into boot code and operational code, both of which are stored in
a flash module. Upon an IPMC reset, the IPMC executes the boot code and performs the following:
a flash module. Upon an IPMC reset, the IPMC executes the boot code and performs the following:
1. Self test to verify the status of its hardware and memory.
2. Sets up the internal real-time operating system (RTOS).
3. Performs a checksum of the operational code.
Upon successful verification of the operational code checksum, the firmware will jump to the
operational code.
operational code.
Table 12.
Link Descriptors for E-Keying
No
Link
Descriptor
Link
Grouping
ID
Link Type
Extension
Link Type
Link Designator
Link Desc
Value
Port 0 -
3 Flags
3 Flags
Interface
Channel
Number
[31:24]
[23:20]
[19:12]
{11:8}
{7:6}
[5:0}
1
Ethernet
Port 1
Port 1
0
0000
00000001
0001
00
000001
0x00001101
2
Ethernet
Port 2
Port 2
0
0000
00000001
0001
00
000010
0x00001102
3
FC Port 1
0
0010
00000010
1000
01
000001
0x00202C41
4
FC Port 2
0
0010
00000010
1000
01
000010
0x00202C42