Chapter 4
VME-MXI-2 Configuration and Installation
© National Instruments Corporation
4-5
Figure 4-3 shows the four intermodule signaling settings.
Figure 4-3.  VME-MXI-2 Intermodule Signaling Settings
MXIbus Termination
The first and last MXIbus devices connected to the MXIbus—whether it is 
a single MXI-2 cable or daisy-chained MXI-2 cables—must terminate the 
MXIbus. Any MXIbus devices in the middle of a MXIbus daisy chain must 
not terminate the MXIbus.
The VME-MXI-2 automatically senses if it is at either end of the MXIbus 
cable to terminate the MXIbus. You can manually control MXIbus 
termination by defeating the automatic circuitry. Use switches 3 and 4 
of the four-position switch at location U21 to control whether MXIbus 
termination is automatic (Figure 4-4a), on (Figure 4-4b), or off 
(Figure 4-4c). The settings of switches 1 and 2 have no effect on MXIbus 
termination.
Use switch 3 to select whether you want the VME-MXI-2 to automatically 
control termination of the MXIbus. Switch 4 lets you manually control 
whether to terminate the MXIbus when automatic termination is turned off.