Troubleshooting Cisco 2800 Series Routers
OL-5789-01
System Messages
Table 3
System Error and Recovery Messages
LED Type
LED Color
Message, Meaning, and Recommended Action
SYS
PWR
PWR
Amber
Error:
%SYS-1-OVERTEMP: System detected OVERTEMPERATURE condition. Please resolve cooling
problem immediately!
Explanation:
The router is operating at an abnormally high temperature, possibly caused by one or more of
the following conditions:
the following conditions:
•
Fan failure
•
Air conditioner failure in the room
•
Air blockage to cooling vents
Recovery:
Make sure that the room temperature is not too high and that airflow to the router is not blocked.
See also the
See also the
and the
.
If this condition persists, the environmental monitor might shut down the system. Call your
Cisco technical support representative for assistance, if necessary.
Cisco technical support representative for assistance, if necessary.
When the error condition is resolved, the SYS PWR LED changes to green, and the following
informational message appears:
informational message appears:
%ENVMON-3-OVERTEMP_OK: System temperature normal
Note
These messages are not supported on the Cisco 2801.
—
—
Error:
%ENVMON-3-FAN_FAILED: Fan fan-number not rotating.
Explanation:
The specified fan (1, 2, or 3) is not rotating at the desired speed.
Recovery:
Make sure that the fan power cable is properly attached to the mainboard fan power connector.
If the problem persists, contact your technical support representative.
If the problem persists, contact your technical support representative.
AUX/
PWR
PWR
Amber
Message:
%ENVMON-5-48V_STATUS: -48V supply failed
Explanation:
The –48 V power supply has failed.
Recommended action:
Replace the power supply. Refer to the
section of the “
” online document.