Cisco CATALYST 6500 2500 WATT AC POWER SUPPLY 规格指南

下载
页码 9
Conventions  
Refer to 
Cisco Technical Tips Conventions
 for more information on document conventions. 
Power Redundancy  
Catalyst 6500/6000 series modules have different power requirements. Certain switch configurations can require more 
power than a single power supply can provide, which depends on the wattage of the power supply. Although the power 
management feature allows you to power all the installed modules with two power supplies, redundancy is not 
supported in this configuration. 
With redundancy enabled, if you power up the system with two power supplies of unequal wattage, both power 
supplies come on line with a corresponding syslog message. The message indicates that the lower-wattage power 
supply will be disabled. If the active power supply fails, the lower-wattage power supply that was disabled comes on 
line. If necessary, certain modules can be powered down in order to accommodate the lower-wattage power supply. For 
more information on the effects of power supply configuration changes, see the 
Effects of Power Supply Configuration 
Changes
 table in this section. 
Note: The Catalyst 6500/6000 series switches allow you to mix AC-input and DC-input power supplies in the same 
chassis. 
Effects of Power Supply Configuration Changes 
Configuration Change 
Effect 
Redundant to 
nonredundant 
System log and syslog messages are 
generated. 
The system power is increased to the 
combined power capability of both 
supplies. 
The modules that are marked as 
power-deny
 in the 
Status
 field of 
the show module command output 
are brought up, if there is sufficient 
power. 
Nonredundant to 
redundant 
System log and syslog messages are 
generated. 
The system power is the power 
capability of the larger-wattage 
supply.  
If there is not enough power for all 
previously powered-up modules, 
some modules are powered down and 
marked as 
power-deny
 in the 
Status
 
field of the show module command 
output. 
Insertion of equal-
System log and syslog messages are 
generated. 
Page 2 of 9
Cisco - Power Management for Catalyst 6000 Series Switches
5/2/2006
http://www.cisco.com/warp/customer/473/142.html