Cisco CATALYST 4500 7 SLOT CHASSIS FAN NO POWER SUPPLY REDUNDANT SUPCAPABLE 规格指南

下载
页码 196
   
4-7
Catalyst 4500 Series Switches Installation Guide
78-14409-08
Chapter 4      Removing and Replacing FRUs
Removing and Replacing the Power Supply
Caution
Use both hands to grasp a power supply.
Step 5
Grasp the power supply handle with one hand. Place your other hand underneath 
to support the bottom of the power supply, as shown in 
.
Figure 4-8
Handling an AC-Input Power Supply
Step 6
Pull the power supply out of the bay and set it aside.
Warning
Blank faceplates and cover panels serve three important functions: they 
prevent exposure to hazardous voltages and currents inside the chassis; they 
contain electromagnetic interference (EMI) that might disrupt other equipment; 
and they direct the flow of cooling air through the chassis. Do not operate the 
system unless all cards, faceplates, front covers, and rear covers are in place. 
Statement 1029
Step 7
If the power supply bay is to remain empty, install a blank power supply filler 
plate over the opening. Secure the filler plate with the two mounting screws and 
tighten them with a screwdriver. 
79141