Power Supplies
The maximum total input current is 42.5A and the maximum ambient temperature
is 55 C. To determine total maximum input power to a supply, add up the active
individual module input power ratings.
is 55 C. To determine total maximum input power to a supply, add up the active
individual module input power ratings.
provides output information for
these modes, given two supplies working in combined mode.
provides
output information for these modes, given two supplies working in redundant
mode.
mode.
Note
In a redundant configuration with all inputs supplied, there must be a 100 W
minimum system load or the OUTPUT FAIL LED shows a false failure.
minimum system load or the OUTPUT FAIL LED shows a false failure.
The C4500 1400 W DC Triple Input SP Power Supply requires a minimum draw
from the system that it is installed in.
from the system that it is installed in.
shows
Table 1-9
Combined Mode Power Supply Configuration
(2450 W Max Output Power)
(2450 W Max Output Power)
Input
Number
Number
Maximum Input Current
Maximum Input
Power @ –44 V DC
Power @ –44 V DC
1
12.5 A @ –44 V DC
550 W
2
15 A @ –44 V DC
660 W
3
15 A @ –44 V DC
660 W
Table 1-10
Dual Redundant Mode Power Supply Configuration
(1400 W Max Output Power)
(1400 W Max Output Power)
Input
Number
Number
Approximate
Input Current
Input Current
Approximate Input
Power @ –40.5 V DC
Power @ –40.5 V DC
Approximate Input
Power @ –44 V DC
Power @ –44 V DC
1
6.25 A @
–40.5 / –44 V DC
–40.5 / –44 V DC
253 W
275 W
2
7.5 A @ –40.5 /
–44 V DC
–44 V DC
304 W
330 W
3
7.5 A @ –40.5 /
–44 V DC
–44 V DC
304 W
330 W