Cisco 7000 SERIES PA 8 PORT T1 MC ADAPTER WITH CSU DSU 规格指南

下载
页码 108
 
1-7
Multichannel DS1/PRI Port Adapter Installation and Configuration
OL-3525-03
Chapter 1      Overview
Cables and Connections
During the system bootup process and microcode download, if an error occurs, the port status LEDs flash 
yellow a number of times, pause, and then repeat the flashes. Count the number of flashes to determine 
the error. 
 lists the LED error indications that might appear.
In all of the preceding error modes, the CPU continually loops and the system does not proceed to the 
microcode download.
After the system successfully completes the CPU boot process and microcode download, the front-panel 
port status LEDs on the multichannel DS1/PRI port adapter show the various system states and 
functions. (See 
.)
Cables and Connections
The DS1/PRI interface receptacles on the multichannel DS1/PRI port adapter are RJ-48C receptacles for 
T1 (100-ohm). You can use all interface receptacles simultaneously. 
Note
After you properly connect a port to a line, it takes approximately 30 seconds for Cisco IOS software to 
report that the line is up.
Table 1-4
LED Error States
Number of 
Yellow 
Flashes
Description
1
Memory tests failed.
2
PLX mailbox test failed.
3
Incomplete data on download.
4
Checksum error on download.
5
Invalid command (flashing does not repeat, but 
processing continues).
6
Unexpected return from downloaded operational 
code.
7
Processor exception has occurred.
Table 1-5
LEDs for Port Status Indications after Boot Completion
LED Color
State
Description
Green
On
Port adapter is receiving good 
signal.
Yellow
On
Port adapter is in loopback 
mode.
None
Off
Not receiving good signal. Not 
in loopback mode.