 ③
 Mount the optical parallel (J15380-2) to the measuring stand(J18037).  
 ④
 Fine adjust the position of the auto-collimeter to adjust the optical axis to the measuring stand.  
 
ref.》
 
The optical axis adjustment is possible by using the parallel glass or parallel mirror, etc, in place of J18037.  
J15380-2
J18037
Auto-collimeter
 ⑤
 Mount the rear lens unit to the measuring stand (J15380-2) and put the parallel glass to the end of the rear lens unit.  
 ※
 The G1 lens for telephoto lens, e.g. AF-S300mm, etc, can be used as parallel glass.
Parallel glass
Mirror tool cross line
Parallel glass cross line
 As shown in the left, measure a gap between the
  
cross line of the mirror tool and that of the paralle
  
glass.  
rear lens unit