Detail program description - Phase assignment
P H A S E A S S I G N M E N T
prior
C
1Nor mal
combi
A
B
D
E
F
2
6
7
Now close one (or more, as required) of the switches 
that you have assigned, and assign one of the fl ight 
phase names from the list you selected beforehand 
on the »Phase settings« menu to this switch position 
or combination. 
Here, for example, we assign the "Launch" phase to 
the closed ("I") priority switch "A" …
P H A S E A S S I G N M E N T
prior
C
2 Launch
combi
A
B
D
E
F
2 I
6
7
… if, for example, we wish to switch to this phase 
regardless of the "C" … "F" switch positions, because 
the same switch activates an electric motor, etc.
Use the same approach to set the other switches or 
combinations of switches.
Theoretically – for the situation where all three are 
closed – you could use the three single switches 
shown in the example to defi ne an additional 
fi fth fl ight phase on the »Phase settings« menu. 
However, since this example assumes just four fl ight 
phases, you can leave the default phase name as «1 
Normal» for this switch position.
Leave this menu in the familiar way, with a tap on the 
center
ESC
 key of the left touch pad.
Tips:
If you have named more phases than you 
currently have switches defi ned for then this is not 
really problematic. You can repeat and change 
your switch assignment as you wish at any point in 
time. And you can also name additional phases at 
any time and then assign switches to them.
When assigning switches, check whether the 
switches are already otherwise assigned to ensure 
that you avoid duplicate assignments.
Important notice:
Before a phase switch is assigned, the model 
settings confi gured are now to be found in the 
fl ight phase «1 Normal», i.e. all fl ight phase-
dependent menus are reset to the standard 
confi gurations for all other fl ight phases.
To avoid having to start from scratch in every 
fl ight phase, you can copy over these standard 
settings by using the command "Copy fl ight 
phase" on the "Copy / Erase" menu to replace 
them with fl ight data obtained from the «Normal» 
fl ight phase. You then need only to make further 
fl ight phase-specifi c changes to the settings.