Hardware Installation
11
Sensor Mounting Screw (1 of 2)
Once the sensor is mounted, connect the supplied cable to the phone jack, and
route the wires over to the controller board. Be careful to avoid pinch points that
might damage the wiring during dome operation.
Wiring
Referring back to the first picture above, you can see the terminal block (green).
Beside that is the dome sensor jack, and the RS-232 serial port connector. The
serial port should be connected to the PC COM port using the supplied cable.
The motor sensor should be plugged into the sensor jack.
The green terminal block includes the following connections, from left to right as
shown in the picture above:
AUX1
Beside that is the dome sensor jack, and the RS-232 serial port connector. The
serial port should be connected to the PC COM port using the supplied cable.
The motor sensor should be plugged into the sensor jack.
The green terminal block includes the following connections, from left to right as
shown in the picture above:
AUX1
Optional. Pulling this terminal to ground will cause the
dome to close
dome to close
AUX2
Optional. Pulling this terminal to ground will cause the
dome to close
dome to close
REED2
Not used.
GND
Not used.
REED1
Home position magnetic reed relay
GND
Ground for home position magnetic reed relay
OPUP/LEFT
LEFT motor command
CLSUP/RIGHT
RIGHT motor command
OPEN
Not used.
CLOSE
Not used.
+12V
+12V input. We recommend adding an external power
switch.
switch.
GND
Ground return for 12V input