List box: Default, Manual,
Default = Default
Default – Default (recommended) values are set and can not be edited.
Manual – Thresholds can be set manually.
SNMP Alarm
List box: Off, On.
Default = Off
If “On”, SNMP Alarm trap is activated. The SNMP trap message is sent both when a parameter
value exceeds the alarm threshold and when it returns back within its “normal” range. Remember
to set the IP destination address for SNMP trap messages. Port number is always 162.
HW Alarm Output
List box: Off, N.O. (Normally Open), N.C. (Normally Closed)
Default = Off
If "N.O." or "N.C.", the HW Alarm Output is active and its normal status (no alarm) is open or closed,
respectively.
The HW Alarm Output is a pin (open n-p-n collector) on the screw terminal at the Power and Control
connector on the front panel.
Detail Graph start
Just for information. It can be set in Settings/Graph/Detail Graph start, not here.
Alarm starts Detail Graph only when this value is set to "Alarm"
HW Alarm Input
List box: Off, N.O. (Normally Open), N.C. (Normally Closed)
Default = Off
If "N.O." or "N.C.", the HW Alarm Input is active and its normal status (no alarm) is open or closed,
respectively.
Alarm event is triggered when the HW Alarm Input changes its status from “Normal” to “Alarm”.
Note that to “Close” the HW Alarm Input means connecting the respective screw terminal at the
Power and Control connector on the front panel to the Ground terminal of the same connector.
When Statistic and Neighbours logs are cleared, RSScom, DQcom, ETH, COM1, COM2 alarms
are cleared as well.
When Hot Standby is “On”, Alarm thresholds and HW alarm input are used internally for switching
between units “A” and “B”. The “HW alarm input” parameter is changed to “Hot Standby active”.
However, SNMP Alarm and Detailed Graphs tick boxes can be used for information about switching
between units “A” and “B”.
Power management
Power supply mode
List box: Always On, Save Mode, Sleep Mode
Default = Always On
Always On
RipEX is always on, no special power saving modes are active.
Save Mode
RipEX is listening on Radio channel in the Save mode while consuming 2.0 W.
Router mode: When the RipEX receives a packet for its IP address, it wakes up. However data
from this first received packet is lost.
Bridge mode: Any packet received on Radio channel wakes the unit up.
○ Timeout
List box: On, Off
Default = On