SPRINGCARD SAS PRNHSP01 用户手册

下载
页码 118
PMD2271-BA
page 102 of 118
S
PRING
C
ARD
 PC/SC C
OUPLERS
 - H663 
GROUP
 - Developer's reference manual
7.4. PC/SC 
CONFIGURATION
7.4.1.
Slot naming and startup mode
Address: 
h
B1 – Size: 1 byte
Bit
Action if set
Note
msb
7
Force a letter in the name of the SAM 
slots
Even if there's only one slot, it will be
named “SAM A”
6
Force a letter in the name of the ID-1 
slots
Even if there's only one slot, it will be
named “Contact A”
5
RFU
4
Prefix the slot name using the product's 
serial number (in hex)
This is useful for computers with 
numerous products attached
3
Start with SAM slot(s) OFF
All the SAM slot(s) will not run until 
resumed by a Control command
2
Start with Contact slot OFF
The Contact slot will not run until 
resumed by a Control command
1
Start with Contactless slot OFF
The Contactless slot will not run until
resumed by a Control command
msb
0
No contactless slot
The Contactless slot will not be 
enumerated (and will never run)
Default value: 
h
00
7.4.2.
CLA byte of APDU interpreter
This register defines the CLA (class) byte affected to the APDU interpreter (see § 3.1.1).
To disable the APDU interpreter, define this register to 
h
00.
Address: 
h
B2 – Size: 1 byte
Default value: 
h
FF
SPRINGCARD, the SPRINGCARD logo, PRO ACTIVE and the PRO ACTIVE logo are registered trademarks of PRO ACTIVE SAS.
All other brand names, product names, or trademarks belong to their respective holders.
Information in this document is subject to change without notice. Reproduction without written permission of PRO ACTIVE is forbidden.