7.4.3.
Behaviour of the contactless slot in PC/SC mode
This register defines the behaviour of the H663's contactless slot in PC/SC mode.
Address: 
h
B3 – Size: 1 byte
Bit
Action if set
Note
msb
7
Innovatron: return the “real” T=0 ATR
(as   supplied   in   REPGEN)   instead   of
building a pseudo ATR
Setting this bit breaks the compatibility
with MS CCID driver, because the card
is   connected   in   T=1   where   its   ATR
claims it is T=0 only
6
Use only standard values for PIX.NN in
the ATR
Numerous contactless PICCs/VICCs 
have not been registered by their 
vendor in the PC/SC specification to 
get a standard PIX.NN.
SpringCard has defined vendor-specific
values for those cards (see 4.1.5).
If this bit is set, these non-standard 
values will not be used, and PIX.NN will
be fixed to 
h
0000 for all PICCs/VICCs 
that are not in the standard.
5
Disable the pause in RF field after the 
PICC/VICC has been removed
When the PICC/VICC stops responding,
the H663 pauses its RF field for 10 to 
20ms. Setting this bit disable this 
behaviour.
4
Disable the pause in RF field after the 
PICC/VICC during the polling
During the polling sequence, the H663 
pauses its RF field for 10 to 20ms 
between the polling loops. Setting this 
bit disable this behaviour.
3
No NFC-DEP activation over Felica
(ISO 18092 @ 212 or 424 kbit/s)
2
No NFC-DEP activation over ISO 
14443-A (ISO 18092 @ 106 kbit/s)
1
No T=CL (ISO-DEP) activation over ISO 
14443-B
Send SLOT CONTROL P1,P2=
h
20,01 to 
activate the PICC manually
lsb
0
No T=CL (ISO-DEP) activation over ISO 
14443-A
Send SLOT CONTROL P1,P2=
h
20,02 to 
activate the PICC manually
Default value: 
h
00 (T=CL active over 14443 A and B, NFC-DEP active over 14443 A and Felica)