SPRINGCARD SAS PRNHSP01 用户手册

下载
页码 118
PMD2271-BA
page 47 of 118
S
PRING
C
ARD
 PC/SC C
OUPLERS
 - H663 
GROUP
 - Developer's reference manual
3.3.7.
ENCAPSULATE instruction for the Contactless slot
The  ENCAPSULATE  instruction has been designed to help the applications communicate with
PICC/VICC that don’t comply with ISO 7816-4.
ENCAPSULATE command APDU for the contactless slot
CLA
INS
P1
P2
Lc
Data In
Le
h
FF
h
FE
See
below
See
below
XX
Frame to send to the PICC/VICC
XX
ENCAPSULATE command parameter P1 for the contactless slot
P1
Standard communication protocols
h
00
For ISO 14443-4 (A or B) PICCs : send the frame in the T=CL stream
Data In shall not include PCB, CID, NAD nor CRC fields
For ISO 18092 targets : send the frame DEP_REQ/DEP_RES stream. Data In shall not
include PFB, DID, NAD nor CRC fields
h
01
Send the frame “as is” using the ISO 14443-3 A protocol @ 106 kbit/s.
The standard parity bits are added (and checked in return) by the H663.
The standard CRC is added (and checked in return) by the H663.
h
02
Send the frame “as is” using the ISO 14443-3 B protocol @ 106 kbit/s.
The standard CRC is added (and checked in return) by the H663.
h
03
Send the frame “as is” using the JIS:X6319-4 protocol @ 212 kbit/s.
The standard CRC is added (and checked in return) by the H663.
h
04
Send the frame “as is” using the ISO 15693 protocol.
The standard CRC is added (and checked in return) by the H663.
h
05
Send the frame “as is” using the ISO 15693 protocol.
The UID of the VICC is added to the frame (unselected access mode).
The standard CRC is added (and checked in return) by the H663.
h
07
Send the frame “as is” using the JIS:X6319-4 protocol @ 424 kbit/s.
The standard CRC is added (and checked in return) by the H663.
…/…
14
This is the only way to send commands to a T=CL PICC that doesn't comply with the ISO 7816-4 APDU formatting, for instance a 
Desfire 0.4.
SPRINGCARD, the SPRINGCARD logo, PRO ACTIVE and the PRO ACTIVE logo are registered trademarks of PRO ACTIVE SAS.
All other brand names, product names, or trademarks belong to their respective holders.
Information in this document is subject to change without notice. Reproduction without written permission of PRO ACTIVE is forbidden.