SPRINGCARD SAS PRNHSP01 用户手册

下载
页码 118
PMD2271-BA
page 53 of 118
S
PRING
C
ARD
 PC/SC C
OUPLERS
 - H663 
GROUP
 - Developer's reference manual
To go back to default (LEDs driven by the H663's firmware automatically), send the APDU:
FF F0 00 00 01 1E
b.
Driving coupler’s buzzer
Some hardware feature a single tone beeper. To start the buzzer, send the APDU:
FF F0 00 00 03 1C <duration MSB> <duration LSB>
where duration specifies the length of the tone, in milliseconds (max is 60000ms).
Set duration to 0000 if you need to stop the buzzer before the duration started in a previous call.
To go back to default (buzzer driven by the H663's firmware automatically), send the APDU:
FF F0 00 00 01 1C
c.
Others
The data block in the  READER CONTROL  instruction is forwarded “as is” to the  reader control
interpreter, as documented in chapter 6.
Therefore, every command documented in § 6.3 and starting with code 
h
58 may be transmitted in
the SCardTransmit link using the READER CONTROL instruction, exactly as if it were transmitted in
SCardControl link.
Do not use this feature unless you know exactly what you are doing.
SPRINGCARD, the SPRINGCARD logo, PRO ACTIVE and the PRO ACTIVE logo are registered trademarks of PRO ACTIVE SAS.
All other brand names, product names, or trademarks belong to their respective holders.