 - Developer's reference manual
3.4.2.
TEST instruction
The TEST instruction has been designed to test the driver and/or the applications, with arbitrary
length of data (in and out).
TEST command APDU
CLA
INS
P1
P2
Lc
Data In
Le
h
FF
h
FD
See
below
See
below
XX
XX … XX
XX
TEST command parameters
Parameter P1 specifies the length of Data Out the application wants to receive from the H663:
h
00: empty Data Out, only SW returned
h
FF: 255 bytes of data + SW
All values between 
h
00 and 
h
FF are allowed
6 low-order bits of P2 specify the delay between command and response.
h
00: no delay, response comes immediately
h
3F: 63 seconds between command and response
All values between 0 and 63 are allowed
2 high-order bits of P2 are RFU and must be set to 0.
TEST response
Data Out
SW1
SW2
XX … XX
See below
Content of Data Out is not specified, and may contain either “random” or fixed data, depending
on the H663 version and current status.