224
Magic String
“OpenMobility” or
“OpenMobilitySIP-DECT”
“OpenMobilitySIP-DECT”
The client uses this option to
select the server, mandatory
select the server, mandatory
* The magic string “OpenMobilitySIP-DECT” instead of “OpenMobility” (as defined in SIP-DECT 2.x)
makes sure that a SIP-DECT software is loaded into the RFP 35/36/37 IP/ RFP 43 WLAN even an
different, non-SIP-DECT SW is previously installed and running.
makes sure that a SIP-DECT software is loaded into the RFP 35/36/37 IP/ RFP 43 WLAN even an
different, non-SIP-DECT SW is previously installed and running.
7.5.4.3 Selecting the Right DHCP Server
The DHCP client requests its own IP address using code 50. The DHCP client will select the DHCP
server that offers the currently used IP address. Additionally the mandatory options must be offered
otherwise the DHCP offer is ignored by the DHCP client.
The DHCP client requests its own IP address using code 50. The DHCP client will select the DHCP
server that offers the currently used IP address. Additionally the mandatory options must be offered
otherwise the DHCP offer is ignored by the DHCP client.
If no matching reply was received, the DHCP client resends the request 2 times after 1 second. Then the
DHCP client will wait for 1 minute before resending 3 requests again.
DHCP client will wait for 1 minute before resending 3 requests again.
If the DHCP client cannot accept a DHCP offer within 30 minutes, the RFP is rebooted.
7.5.5 RFP LED STATUS
RFP 32/34 IP
RFP 32/34 NA
RFP 35/36 IP
RFP 32/34 NA
RFP 35/36 IP
RFP 42 WLAN
RFP 43 WLAN
RFP 43 WLAN
LED 1 Info / Booter; LED 2 System;
LED 3 DECT; LED 4 (unused)
LED 1 Info / Booter; LED 2 System
LED 3 DECT; LED 4 WLAN
The following tables show the LED status of an RFP according to the different states.
A red respectively orange colored field in the table means that the LED glows permanently in red or
orange. A split field with e.g. the specification 1s/1s means that the LED is flashing with a frequency of