Infrastructure Requirements and Layout Planning 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
12
 
3.3 
Coverage and Installation Planning 
Note: The following section provides information required for planning the VAP installation on a 
single floor. In a multi-tier installation, this procedure is performed for each individual floor.  
The  maximal  coverage  area  of  each  VAP  is  affected  by  the  density  and  type  of  environment 
being covered. Therefore, it is recommended to determine the location in two phases: 
  Plan the 
ideal location of each VAP in order to achieve complete coverage of the floor. 
  Select the 
exact location according to the location feasibility, where each VAP unit may be wall 
or desk mounted and an option for an external antenna is available. 
The supplied services (wireless only or Ethernet and wireless) depend on the jack to which the 
VAP is connected:  
  If  the  jack  supports  an  active  Ethernet  connection,  the  VAP  will  distribute  LAN  traffic  along 
with the wireless service. (See section 4.3). 
  If the jack is not currently active (not connected to an Ethernet switch), the VAP will distribute 
only the wireless services. 
This section provides information  on coverage criteria in various types of environments (Open, 
Standard, Dense and Merged) and provides rules-of-thumb for various installations of the VAPs.  
Note:  Section  3.4  provides  a  detailed  example  of  installation  planning  in  various  types  of 
environment. It is recommended to review this example after reading this section. 
3.3.1 
Types of Environments 
This section describes the different types of installation environments and provides guidelines for 
best coverage of each type of space. 
The  coverage  guidelines  in  this  section  are  conservative  “rule  of  thumb”  estimates  of  RF 
coverage per VAP, meant to be used in scenarios in which detailed designs are not performed. 
When the coverage layout is designed, the coverage per VAP is expected to  increase by up to 
33%.  Coverage  estimates  in  this  section  assume  25%  overlap  between  the  coverage  areas  of 
neighboring  VAPs  to  ensure  robust,  full  coverage  throughout  the  enterprise  with  no  “dead 
zones”.