Corning Optical Communication Wireless MAVELTE700L 用户手册

下载
页码 91
Infrastructure Requirements and Layout Planning 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
15
 
 
3.4.4 
Installation Plan Example 
The following figure shows a floor plan map with all required marks: 
 
Figure 3-2. Floor Plan Example 
Notes: 
  The  red  VAP  coverage  circles  have  an  approximate  radius  of  41,  56,  and  64  foot  (13.5,  19, 
and  21  meters)  for  the  small,  medium,  and  large  circles  respectively,  which  are  drawn 
according to the guidelines given in section 3.3.1. 
  VAP  3  is  surrounded  by  the  bathroom  and  stairwell  which  are  considered  dense  objects  and 
would reduce coverage in that area by the other VAPs. 
  VAP  5  is  an  example  of  a  unit  that  provides  good  coverage  down  the  hallways  in  an  Open 
Environment. 
  VAPs 11 and 13 are placed closer to the offices to provide better coverage to them, but on the 
open  side  will  actually  cover  a  much  greater  area.  This  is  why  the  coverage  is  larger  and 
shown here more as an oval than a circle. 
  The area between VAPs 7 and 14 would probably be the lowest coverage spot in the building 
because  of  the  bathrooms  and  stairwell  on  either  side.  If  after  the  system  is  installed,  this 
area is still a little low on coverage, a VAP can be added, but it may also be covered by VAP 
14. 
Note: The plan can be modified at any time by moving the units around or by adding units.