Corning Optical Communication Wireless MAVELTE700L 用户手册

下载
页码 91
VCU Unit Installation and Provisioning 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
30
 
Note: The MIMO DL CF parameter is Read Only and pre-defined for the supported 10 MHz 
block.  The  MIMO  DL  CF  parameter  defines  the  same  DL  central  frequency  from  the  Base 
Station for Channel 1 and Channel 2. 
2.  Define Max expected power of BTS (0-33dBm). 
3.  Define UL System Gain (-15 to 5dB) 
Notes:  
1.  Max expected Pin parameter can be obtained from your service provider. 
2.  The remaining parameters are predefined to their default values. (Service Bandwidth is 
set to 10MHz per channel). 
3.  Any updates of the service definition (Service Mode) are sent to all connected VAPs. 
To Configure the SISO RF Parameters: 
Note: The RF tab is displayed for MIMO by default. 
1.  Select the Master VCU in the topology tree and select the SISO option in the Service Mode 
drop-down list. The RF parameters tab will display the SISO RF parameters. 
 
 
2.  Define Max expected power of BTS (0-33dBm). 
3.  Define UL System Gain (-15 to 5dB) 
Service Mode 
drop-down list