Corning Optical Communication Wireless MAVELTE700L 用户手册

下载
页码 91
VCU Unit Installation and Provisioning 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
32
 
Note: To briefly check the VCU status, click on the VCU name in the Topology Tree. The VCU 
icon will appear, showing the LEDs status. 
 
2.  Mask  irrelevant  alarm  conditions  to  avoid  affecting  the  overall  status  of  the  unit.  See 
following example. 
For Example 
Note: Channel DL signal refers to the  MIMO/SISO DL signal from the BS side  towards the 
remote units (VAPs). 
In the example below “Channel 2 RF DL Pwr High” alarm is masked (Disabled). This is the 
alarm 
for the DL signal (from the BS side). 
The left dialog shows the alarm response when Channel 2 DL RF Pwr High alarm is enabled 
and  a  fault  corresponding  to  that  alarm  is  detected.  (MIMO  2  DL  RF  Power  exceeds  the 
defined range). The overall status will be RED indicating a fault. 
The right  side  dialog shows the alarm response when  Channel  2  DL  RF Pwr  High alarm is 
masked  (Disabled).  The  Channel  2  DL  RF  Pwr  High  LED  will  appear  RED;  but,  the  overall 
status will be GREEN, showing NO Fault.  
              
    
 
                   Figure 4-3. Service2 Service Off Alarm 
– Unmasked       Figure 4-4. . Service2 Service Off Alarm –Masked 
Overall Status RED 
Click VCU Master 
Overall Status GREEN