WinLink 1000 Installation and Operation Manual 
Chapter 
 
5  Diagnostics and Troubleshooting 
 PM 
Running Diagnostic Loopbacks 
5-5 
Testing 
Equipment 
Management 
Station
E1
Interface
/T1
Local ODU
 
Figure 
 
5-3.  Local External Loopback 
Remote Internal Loopback 
Remote WinLink 1000  can be set to an internal loopback to test 
connection between the local and remote units, the local E1/T1 port 
and its connection to the local side user equipment. In this mode, data 
coming from the local WinLink 1000  is looped back to it (see 
Figure 
 
5-
4
). This loopback is initiated from a management station connected to 
the local unit. 
Management 
Station
E1/T1
Interface
E1
Interface
/T1
Testing 
Equipment
Remote ODU
Local ODU
 
Figure 
 
5-4.  Remote Internal Loopback 
Remote External Loopback 
Remote WinLink 1000  can be set to an external loopback to test the 
remote E1/T1 port and its connection to the remote side user 
equipment. In this mode, data coming from the remote user equipment 
is looped back to it (see 
Figure 
 
5-5
). This loopback is initiated by an 
inband command sent from a management station connected to the 
local unit.