Chapter 5  Diagnostics and Troubleshooting 
AirMux-104 Installation and Operation Manual 
5-6 
Running Diagnostic Loopbacks
 
 
Remote External Loopback 
Remote AirMux-104 can be set to an external loopback to test the remote E1 port 
and its connection to the remote side user equipment. In this mode, data coming 
from the remote user equipment is looped back to it (see 
loopback is initiated by an inband command sent from a management station 
connected to the local unit. 
Testing 
Equipment 
Management 
Station
E1 
Interface
E1 
Interface
Local RT
Inband Loopback
Activation Command
Remote RT
 
Figure 5-7.  Remote External Loopback 
Local Internal Loopback 
Local AirMux-104 can be set to close an internal loopback to test connection 
between the local and remote units, remote E1 port and its connection to the 
remote side user equipment. In this mode, data coming from the remote user 
equipment is looped back to it (see 
). This loopback is initiated by an 
inband command sent from a management station connected to the local unit. 
Testing 
Equipment 
Management 
Station
E1 
Interface
E1 
Interface
Local RT
Inband Loopback
Activation Command
Remote RT
 
Figure 5-8.  Local Internal Loopback