Table 40: Troubleshooting - Event Log Messages
Log Message
Description
Synchronization with GPS
Ok
Ok
Synchronization with an external GPS clock has been
successfully completed.
successfully completed.
Synchronization with
Master is Lost
Master is Lost
A backup slave has previously detected the presence of
a master clock signal, and synchronized. It has since
lost this signal.
a master clock signal, and synchronized. It has since
lost this signal.
Synchronization with
Master Ok
Master Ok
A slave has successfully synchronized with a master’s
clock signal
clock signal
Synchronization Signal
Detected
Detected
A Slave has detected the clock signal of a Master.
Synchronization Signal not
Detected
Detected
A slave has previously synchronized with a Master, but
has since lost the signal.
has since lost the signal.
WARNING: Clock Offset
Close to End of Scale
Close to End of Scale
The reference clock calibration procedure initiated by
the user has been completed, but the clock offset is at
the boundaries of the base station’s capabilities
the user has been completed, but the clock offset is at
the boundaries of the base station’s capabilities
WARNING: DL aggregated
Guaranteed Rate exceeds
Capacity
Guaranteed Rate exceeds
Capacity
The aggregate guaranteed minimum rates configured
for service flows using RTPS and UGS scheduling
exceeds the downlink capacity of the sector.
for service flows using RTPS and UGS scheduling
exceeds the downlink capacity of the sector.
WARNING: Indoor Unit
Temperature > 65 Celsius
Temperature > 65 Celsius
The base station indoor unit has exceeded the
recommended operating temperature.
recommended operating temperature.
WARNING: ODU
Temperature is [c] Celsius
Temperature is [c] Celsius
The operating temperature of the base station ODU is
nearing the limit of its operating temperature. No action
is taken.
nearing the limit of its operating temperature. No action
is taken.
WARNING: Power Supply
[X] is Off
[X] is Off
Where X is either A or B. This signifies that the relevant
power supply has been detected, but it is not supplying
power to the base station.
power supply has been detected, but it is not supplying
power to the base station.
WARNING: UL aggregated
Guaranteed Rate exceeds
Capacity
Guaranteed Rate exceeds
Capacity
The aggregate guaranteed minimum rates configured
for service flows using RTPS and UGS scheduling
exceeds the uplink capacity of the sector.
for service flows using RTPS and UGS scheduling
exceeds the uplink capacity of the sector.
WRONG CRC over I2C
The stored interface configuration data has failed
integrity check.
integrity check.
WARNING: Unknown
Interference was detected
on the UL channel
Interference was detected
on the UL channel
During startup, a long preamble was received but no
DL-Map was detected the UL channel.
See section 7.6: Detecting Channel Interference at
Startup on page 97.
DL-Map was detected the UL channel.
See section 7.6: Detecting Channel Interference at
Startup on page 97.
WARNING: RF Channel
Conflict with [BS Id]
Conflict with [BS Id]
During startup, a long preamble and DL-Map were both
detected on the UL channel. See section 7.6: Detecting
Channel Interference at Startup on page 97.
detected on the UL channel. See section 7.6: Detecting
Channel Interference at Startup on page 97.