Redline Communications Inc. AN100UA 用户手册
Red
MAX
™
Base Station
User Manual
Doc. #70-00058-01-01
Proprietary Redline Communications © 2007
July 13, 2007
Page 106 of 119
Table 41: Specifications - RedMAX Base Station
Range:
20 km (13 miles) LOS
3 km (2 miles) non LOS
Wireless Transmission:
256 FFT OFDM (orthogonal frequency division multiplexing)
Network Connections:
RJ-45 (10/100 Ethernet)
System Configuration:
HTTP (Web), SNMP, FTP (software updates)
CLI via Local Console (RS-232) only
Network Management:
SNMP, standard and proprietary MIBs
Full management by RedMAX Management Suite
Power Requirements:
Auto-sensing 90-264 VAC (47-63 Hz)
Auto-sensing 21 - 60 VDC, 75 W maximum
Optional dual AC or dual DC power supply
(dual cord with automatic failover)
Standards: IEEE:
802.3,
802.3x, 802.1Q, 802.1p.,802.16-2004
ITUT: G.711, 723, 726, 729, 168 (VoIP codec)
Compliance:
EMC: EN 301 489-1, EN 301 489-4, (EN 55022/CISPR 22)
IEC 61000-4-5 class 3 (2 KV), ITU-T K.21
ESD as per EN 61000-4-2.
Radiated Immunity as per EN-1000-4-3.
EFT as per EN 61000-4-4
Surge as per EN 61000-4-5
Conducted Immunity as per EN 61000-4-6
Dips & interrupts (AC versions only) as per EN 61000-4-11
Flickers and harmonics (AC versions only) comply to
EN 61000-3-2, EN 61000-3-3
RF: EN 302 326, Industry Canada: RSS-192
Safety: IEC 60950-1, UL 60950-1
Operating Temperature:
IDU: 0 C to 40 C
IDU Short-term: 0 C to 55 C for up to 5 hours
ODU: -40 C to 60 C
Wind Loading:
Antenna: 220 Km/hr (137 mph)
Dimensions:
431.8 x 304.8 x 44.45 mm (17 x 12 x 1.75 in)
Weight:
2.5 Kg (5.5 lb)
Humidity:
Up to 90% non-condensing
1
Actual Ethernet data throughput is dependent on channel size, protocols, packet size, burst
rate, transmission latency, and link distance.