7.6 
RedMAX Backhaul Application 
The RedMAX equipment can be configured to operate as a PTP backhaul link to provide 
backhaul services  to  a  remote  location  (e.g.,  RedMAX  PMP  network). This  can  reduce 
capital  and  operational  expenses  (training,  spare  parts,  etc)  when  compared  to 
purchasing other models or  manufactures equipment to provide this service. There are 
no hardware, software, or configuration changes required for any RedMAX subscriber or 
base station used for backhaul operations. 
7.6.1  Base Station Configuration 
There  are  three  specific  configuration  settings  required  to  enable  the  RedMAX  base 
station for backhaul operation (no configuration change is required for the subscriber). 
Service Class 
Create one service class with the following settings: 
SC Name
 
Backhaul 
Scheduling Type
BE
 
Traffic Priority 
0 
Max Sust Rate 
25400000 
Service Flows 
Click 
Service Flows
 
in the menu (left side of screen) and create two service flows with 
the following settings. Enter the following settings for the upstream service flow. 
SS Name
 
[subscriber name] 
Direction
 
upstream 
SC Name
 
Backhaul 
Cs Specification
802.3 Ethernet
Enter the following settings for the downstream service flow. 
SS Name
 
[subscriber name] 
Direction
 
downtream 
SC Name
 
Backhaul 
Cs Specification
802.3 Ethernet
Classifiers 
Click 
Classifiers
 
in  the  menu  (left  side  of  screen)  and  enter  the  same  settings  for  the 
upstream and downstream service flows: 
DestMacAddr: Check   to enable field. Enter a value of all zeros (00:00:00:00:00:00). 
DestMacMask: Enter a mask of all zeros (00:00:00:00:00:00). 
Synchronization 
Click  Wireless  Interface  in  the  menu  (left  side  of  screen)  and  select  the  following 
settings in the MAC Parameters section of the page: 
Adaptive  TDD:  Check 
  box  to  activate  dynamic  uplink/downlink  setting.  A  log 
message  is  created  when  Adaptive  TDD  is  enabled  and  disabled.  This  feature  is 
enabled only when Synchronization Mode = No Sync.
 
Synchronization  Mode:  No  Sync  The  synchronization  function  must  be  disabled  to 
enable use of the Adaptive TDD.