Redline Communications Inc. AN100UXA 用户手册

下载
页码 136
 
 
 
User
 
 
AN-100U/UX Base Station
 
Manual
 
 
 
70-00058-01-04 
Proprietary Redline Communications © 2010  
Page 126 of 136 
April 19, 2010 
take the base station more than 25 seconds to declare a subscriber unavailable and 
mark  it  as  de-registered.  During  the  same  25-second  period,  the  subscriber  may 
declare the base station to be unavailable (i.e., due to poor link conditions) and begin 
attempts  to  re-register.  In  this  scenario,  the  subscriber  is  attempting  to  re-register 
before the base station has declared the subscriber to be failed.  
2.  This condition may also result from a loss of connectivity between a subscriber and 
the  DHCP  server  or  TOD  server.  When  remote  management  is  enabled  on  the 
subscriber (managedSS=1), the subscriber must communicate with the DHCP server 
and  the  ToD  server  specified  in  the  obtained  lease.  If  communication  cannot  be 
established  within  two  minutes,  the  subscriber  MAC  is  rebooted  and  the  attempt 
repeated. 
8.9 
Replacing the System Fuse 
Important:  Always  completely  remove  power  from  the  base  station  before  performing 
any maintenance on the terminal or modem. 
 
Warning to service personnel: 
Caution for all AC and DC models 
– Double Pole/Neutral fusing.
 
To replace fuse: 
1. 
Disconnect power from the terminal. 
2. 
Pry  off  the  black  plastic  cover  located  on  the  back  panel  beside  the  power  switch 
and  extract  the  red  fuse  holder.  Use  an  approved  tool  to  remove  the  glass-cased 
fuses  from  the  holder.  Be  certain  to  replace  the  fuse(s)  into  the  lower  half  of  the 
holder,  as  shown  in  the  diagram  below.  The  fuse  holder  holds  two  fuses,  both  of 
which are active. Be certain to use fuses of the same type and rating. 
3. 
Replace the fuse holder in the system terminal and secure. 
4. 
Restore power to the base station. 
 
Figure 44: Diagnostics: Base Station Power Supply Fuse Holder 
 
Table 63: Troubleshooting - Fuse Ratings 
Symptom 
Power Supply 
Type 
Fuse Rating 
AN-100U 
AC 
2.5 Amp, 5 x 20 mm, time delay glass tube 
DC 
4.0 Amp, 5 x 20 mm, time delay glass tube 
AN-100UX 
AC 
2.5 Amp, 5 x 20 mm, time delay glass tube 
DC 
5.0 Amp, 5 x 20 mm, time delay glass tube 
 
Redundant DC 
5.0 Amp, 5 x 20 mm, time delay glass tube