Redline Communications Inc. AN100UXA 用户手册
User
AN-100U/UX Base Station
Manual
70-00058-01-04
Proprietary Redline Communications © 2010
Page 126 of 136
April 19, 2010
take the base station more than 25 seconds to declare a subscriber unavailable and
mark it as de-registered. During the same 25-second period, the subscriber may
declare the base station to be unavailable (i.e., due to poor link conditions) and begin
attempts to re-register. In this scenario, the subscriber is attempting to re-register
before the base station has declared the subscriber to be failed.
mark it as de-registered. During the same 25-second period, the subscriber may
declare the base station to be unavailable (i.e., due to poor link conditions) and begin
attempts to re-register. In this scenario, the subscriber is attempting to re-register
before the base station has declared the subscriber to be failed.
2. This condition may also result from a loss of connectivity between a subscriber and
the DHCP server or TOD server. When remote management is enabled on the
subscriber (managedSS=1), the subscriber must communicate with the DHCP server
and the ToD server specified in the obtained lease. If communication cannot be
established within two minutes, the subscriber MAC is rebooted and the attempt
repeated.
subscriber (managedSS=1), the subscriber must communicate with the DHCP server
and the ToD server specified in the obtained lease. If communication cannot be
established within two minutes, the subscriber MAC is rebooted and the attempt
repeated.
8.9
Replacing the System Fuse
Important: Always completely remove power from the base station before performing
any maintenance on the terminal or modem.
any maintenance on the terminal or modem.
Warning to service personnel:
Caution for all AC and DC models
– Double Pole/Neutral fusing.
To replace fuse:
1.
Disconnect power from the terminal.
2.
Pry off the black plastic cover located on the back panel beside the power switch
and extract the red fuse holder. Use an approved tool to remove the glass-cased
fuses from the holder. Be certain to replace the fuse(s) into the lower half of the
holder, as shown in the diagram below. The fuse holder holds two fuses, both of
which are active. Be certain to use fuses of the same type and rating.
and extract the red fuse holder. Use an approved tool to remove the glass-cased
fuses from the holder. Be certain to replace the fuse(s) into the lower half of the
holder, as shown in the diagram below. The fuse holder holds two fuses, both of
which are active. Be certain to use fuses of the same type and rating.
3.
Replace the fuse holder in the system terminal and secure.
4.
Restore power to the base station.
Figure 44: Diagnostics: Base Station Power Supply Fuse Holder
Table 63: Troubleshooting - Fuse Ratings
Symptom
Power Supply
Type
Type
Fuse Rating
AN-100U
AC
2.5 Amp, 5 x 20 mm, time delay glass tube
DC
4.0 Amp, 5 x 20 mm, time delay glass tube
AN-100UX
AC
2.5 Amp, 5 x 20 mm, time delay glass tube
DC
5.0 Amp, 5 x 20 mm, time delay glass tube
Redundant DC
5.0 Amp, 5 x 20 mm, time delay glass tube