8.10  RF Troubleshooting 
The terminal monitors the status of the outdoor modem and reports any fault conditions 
in the system event log. The following table lists the general fault conditions reported by 
the terminal. 
Table 64: Troubleshooting - RF Error Diagnostics 
Error Type 
Description 
IF PLL Unlocked 
The PLL (Phase Locked Loop) section within the terminal 
experienced an error. The System Fault LED may light. Try 
rebooting the base station. 
Communication Error 
Over IF Cable 
Communication between the terminal and the modem failed. 
Check the IF cable and connectors. 
Outdoor Unit 
Temperature is too 
High. Air Interface 
Disabled for 15 Minutes 
The internal temperature of the modem is above 82C 
(180°F). The modem shuts down to allow cooling. 
Outdoor Unit Power 
Supply Error 
Displays a fault in the modem power supply. This error 
could be due to a problem with the internal power supply or 
with the power source from the terminal. If the 'Low DC 
Voltage At Radio' error is also indicated, (see below) check 
the IF cable and connectors. If the 'Low DC Voltage At 
Radio' error is not indicated, the modem requires servicing. 
Outdoor Unit 24V Error 
The DC voltage at the modem (carried by the IF cable from 
the terminal) is lower than the required 24 VDC. Check the 
IF cable and connectors. The minimum required voltage for 
operation is 12 VDC. 
Air Interface Disabled 
The radio is disabled. 
Cable Compensation 
Failed 
The measured IF cable compensation is out of specification. 
Invalid Radio 
The attached radio is not compatible with this 
terminal/configuration. 
Outdoor Unit 3.3V Error 
The modem internal power supply is lower than the required 
3.3 VDC.  
 
8.11  Debug Mode 
Debug  mode  is  used  for  factory  test  and  advanced  troubleshooting.  Logging  in  to  the 
Web GUI or Telnet session using the debug username and password provides access to 
advanced  configuration  controls.  Debug  mode  should  be  used  only  under  the  explicit 
direction  of  Redline field  service  or  their representatives.  It  is  recommended  to change 
the debug mode default password to restrict access to this feature.