Redline Communications Inc. AN100UXA 用户手册

下载
页码 136
 
 
 
User
 
 
AN-100U/UX Base Station
 
Manual
 
 
 
70-00058-01-04 
Proprietary Redline Communications © 2010  
Page 97 of 136 
April 19, 2010 
Table 43: CLI - Show Command 
Command 
Parameter/Description 
 
SignalNoise:..................29.6 dB 
   IpAddress:....................192.168.20.30 
 
SignalNoiseMax:...............31.1 dB 
   BasicCid:.....................47 
 
 
SignalNoiseMin:...............23.2 dB 
   DownChannelModCode:...........64QAM(3/4)(6)
 
CrcErr:.......................0 
   SsInfDownlinkRate:............12705 Kbps
 
AntennaRsl:...................-54 dBm 
   UpChannelModCode:.............64QAM(3/4)(6)
 
Distance:.....................0 m 
   SsInfUplinkRate:..............12705 Kbps
 
status  
Display Wireless Interface information. 
AN100UX(show->)$> status 
  Structure ---  <<Wireless Interface Status>> 
 
   Downlink Status                        Uplink Status 
   -------------------------------------  ------------------------------- 
   Traffic:.......................0 kbps  Traffic:.................0 kbps 
   BandwidthMargin:...........13824 kbps  BandwidthMargin:......3110 kbps 
   ActiveSfs:.....................0       ActiveSfs:...............0 
   SmcRate:.......................0 kbps  SmcRate:.................0 kbps 
   BwUsage:.......................0 %     BwUsage:.................0 % 
 
   Others 
   ------------------------------------- 
   Cinr:........................3.0 dB 
   RfTxPower:....................20 dBm 
   IduTemp:...................41 Celsius 
   OduTemp:...................33 Celsius 
   HcsErrors:.....................0 
   CrcErrors:.....................0 
   AirInterfaceStatus:...enabled(1) 
   ScSynchroStatus:....noSynchro(0) 
   RegisteredSSs:.................0 
   ReferenceRss:................-70 dBm 
   PowerSupplyStatus:......AB-On(3) 
   FansStatus:..............main(1) 
   NarrowestSubchannel:1/2-Subch(1)
 
sysContact 
Display contact info of system administrator. 
sysDescr 
Display info about system hardware and software. 
sysLocation 
Display system location information. 
sysName 
Display system name. 
sysUpTime 
Display system time running since last reboot. 
version 
Display the running software version. 
 
 
5.2.10  snmpAccCtrl 
Use  the  snmpAccCtrl  command  to  enable  access  for  SNMP  managers.  All  SNMP 
managers  are  identified  by  IP  address,  port,  and  community  read  and  write  names 
(strings) and can be individually added and removed from the list.  
Table 44: CLI - snmpAccCtrl 
snmpAccCtrl <add> <alias> <delete> <edit> <show> 
Configure SNMP account access settings. 
add <Entryindex> <ReadCommunity> <WriteCommunity> <ManagerIpAddress> 
Create a new  SNMP trap.  The index value is assigned automatically. Up to eight settings 
may be entered.