Redline Communications Inc. AN50S 用户手册

下载
页码 76
 
 
AN-50 System User Manual 
 
Redline Communications 
 
…..solving the first mile challenge
 
 
Software Version: Specifies the current version of the system software. Note that 
software can be remotely downloaded into the AN-50 terminal. The system includes 
sufficient memory to hold two independent software loads. The operator can specify 
which software load is used in the system. See section 8.6 for additional details. 
 
Mode:  Sets the AN-50 to serve as the PMP master, PTP master or PMP / PTP slave. 
One and only one unit must be set as the master. A slave will not communicate with 
another slave. 
 
Alignment Mode: Specifies the current alignment mode: buzzer or vu-meter (future 
release). The buzzer provides an alignment tone sweep generator located in the T-58 
Transceiver for fine-tuning based on signal strength. Faster repetitions of the tone sweep 
indicate better alignment.  
 
Options Key: The key is personalized to each unit’s MAC address. The 64 QAM 
License Key (an optional purchase item) raises the available Uncoded Burst Rate from 
the default 36 Mbps to 54 Mbps. Please ensure that the correct MAC address is 
provided when requesting a key from your local Redline representative, or register 
directly at 
. Enter the key (case 
sensitive), ensure it is correct, and click "Send Key". Please note that the system cannot 
be used without the option key. 
 
 
IP Configuration: 
 
IP address: This field is used to provide an IP address for the local AN-50 terminal.  The 
default address from the factory is 192.168.25.2. For the initial setup, the terminal should 
not be connected to the Internet, i.e., the host computer should be connected directly to 
the terminal Ethernet port, to avoid address conflicts with other devices on a public 
network. Once an IP address has been set, the terminal can be connected to the core 
network.   
 
IP Subnet Mask: This field is used to set the desired IP subnet mask. The default mask 
value is set to "255.255.255.0” (Class C subnet). 
 
Default Gateway Address:  Specifies the IP address of the default router / gateway on 
the local Ethernet segment. The default gateway address is 192.168.25.1 
 
 
Wireless Configuration: 
 
Max RF Power: this parameter specifies the maximum power level of the system. 
Depending on the RF channel, FCC regulations and / or local / regional regulation, the 
user must follow the table below when determining the power to be used. 
 
Page 30 of 76