5.4 
Troubleshooting the Web Interface 
The following table lists some common troubleshooting tips for the web interface. 
Table 22: Diag. - Web Interface Diagnostics 
Symptom 
Possible 
Problem 
Solution 
Incorrect IP 
address and/or 
subnet mask. 
Perform a ping test from the host computer 
command line. 
If the ping test is unsuccessful, then the problem 
is with the IP address. Perform a long reset to 
apply the default address (192.168.25.2) and 
Subnet Mask (255.255.255.0) 
Problems with 
host computer, or 
AN-80i. 
If the ping is successful, reset the AN-80i, and/or 
reset the host computer. 
General 
Information 
screen is not 
displayed 
Host PC ARP 
table is 
incorrectly 
configured 
Run 'arp -d' whenever the AN-80i is swapped. 
Check that the subnet mask for the host PC 
matches the subnet mask of the AN-80i. Check 
that the host PC's address is 192.168.25.n, 
where 'n' is not equal to 0,2, or 255. 
 
Attempt to login to the AN-80i using a Web browser. Microsoft Internet Explorer is 
recommended. If the AN-80i does not respond by displaying the login dialog box, check 
that the correct IP address is being used. The value 192.168.25.2 is the factory default 
value and may have been changed during installation. 
Test is to verify the IP address is reachable from the computer. Use the ping command to 
test the connection between the AN-80i and host computer. 
>ping 192.168.25.2 
If the ping test is successful, the host computer was able to send and receive packets 
to/from the AN-80i. The problem may be with the Internet browser or related settings on 
the host computer. Reboot the host computer to try to resolve the problem. 
If the ping is unsuccessful, there may be problems using that IP address; the IP address 
may be incorrect, or there may be a duplicate address. For correct operation the host 
computer and the AN-80i must be on the same subnet. For example, if the AN-80i is 
using the factory default settings, the host computer could be set for an IP of 
192.168.25.3 and a subnet mask of 255.255.255.0. 
If the correct IP address of the AN-80i cannot be determined, it is recommended to 
perform the IP recovery procedure. See 5.2: Procedure to Reset AN-80i IP Address on 
page 49.