Redline Communications Inc. AN80IE 用户手册

下载
页码 106
 
 
&
 
 
User 
 
AN-80i 
Manual
 
 
70-00072-01-07 
Proprietary Redline Communications © 2010 
Page 21 of 106 
Sept 18, 2008 
 
 
Table 3: Wireless Signal LED Indication 
Adaptive Modulation 
 
Enabled 
The Wireless Signal LED lights solid green when the wireless link is 
operating at the rate equal to the Uncoded Burst Rate setting, and 
blinks when operating at a lower rate. 
Disabled 
The Wireless Signal LED lights solid green when the wireless link is 
established. 
 
If the LED is off, it may indicate one of the problems listed in the following table: 
Table 4: Wireless Signal LED Diagnostics 
Symptom 
Possible Problem 
Solution 
 
Weak RF 
Link 
Obstructions in the propagation path 
causing signal degradation.  
Try to remove obstacles or re-locate 
antenna.  
Antenna moved, due to high winds. 
Re-align the antenna. 
 
Ethernet Link LED 
The Link LED lights solid green when there is an Ethernet connection and no traffic, and 
blinks when traffic is detected. If the LED is off, it may indicate one of the problems listed 
in the following table: 
Table 5: Ethernet Link/Act LED Diagnostics 
Symptom 
Possible Problem 
Solution 
 
No Ethernet 
Link 
Poor cable connection to Ethernet 
equipment. 
Carefully check all cable connections. 
Wrong type of cable to Ethernet 
equipment. 
If the Ethernet is connected to a 
router, a straight-through cable is 
required. If the Ethernet is connected 
to a switch, a crossover cable is 
required. 
System processor malfunction. 
Apply short reset or long reset.  
The connected Ethernet equipment 
may be malfunctioning. 
Repair or replace faulty equipment. 
 
Ethernet 100 LED 
The Ethernet 100 LED lights solid green when the Ethernet port is operating at 100 Mb/s 
and  is  off  when  operating  at  10  Mb/s.  If  the  LED  is  off,  it  may  indicate  one  of  the 
problems listed in the following table: 
Table 6: Ethernet 100 LED Diagnostics 
Symptom 
Possible Problem 
Solution 
 
Ethernet 10 
Mbps 
AN-80i is manually set for 
10Base-T operation and 
connected device is operating at 
100Base-T or auto-negotiate. 
It is strongly recommended to manually 
configure all devices to matching speed 
and duplex settings. If manual settings are 
not available, both devices must be set to 
auto-negotiate. 
The connected Ethernet device is 
operating at 10Base-T. 
If the AN-80i is connected to a host 
computer or server operating at 10Base-T, 
this is normal operation.