Part No R0610401 
Description: 
Installing a Budderfly adapter transforms your building’s existing wiring into the “Budderfly Open Network” and allows
the adapter to monitor energy consumption and communicate the data to a facility controller.  
Budderfly adaptors use the existing power line for communication and thus require no re‐wiring. 
Using our Budderfly software, you can visualize consumption data and manage each individual adapter. 
As  a  component  of  Budderfly  system,  the  Budderfly  Controllable  Outlet  is  designed  to  work  with  all  other  Budderfly
adapters.  It  is  a  plug‐and‐play  replacement  for  your  existing  duplex  outlet,  and  it  provides  control  on  one  of  its  two
sockets. Once installed, The Budderfly Controllable Outlet also acts as a repeater to extend the range of the network and
increase efficiency. 
 
 
Installation: 
The Budderfly Controllable Outlet may be used in new installations or to replace an existing Outlet. The wiring schematic will be as per below:
 
1.  At  the  circuit  breaker  or  fuse  panel,  disconnect  the  power  for  all  of  the
circuits in the switch junction box.  
2.  Double Check that the power is OFF to the Outlet by trying to turn on a
device connected to the plug before continuing. 
3.  Remove the wall plate from the outletyou are replacing. Then, unscrew the
outlet itself and pull it out from the junction box. 
4.  Disconnect the wires from the outlet you are replacing. 
5.  Follow  the  Wiring  information  provided  below  and  connect  the  wires  as
follows: 
‐  Connect the GROUND wire (usually Bare Copper or Green) to the Ground
wire of Budderfly Controllable Outlet (Yellow & Green). 
‐  Connect the LINE wire (usually Black) that comes from the electrical service
panel to the HOT wire of Budderfly Controllable Outlet (Black). 
‐  Connect the NEUTRAL wire (usually White) to the Neutral wire of Budderfly
Controllable Outlet (White). 
6.  After  you  have  connected  all  of  the  wires,  ensure  that  all  of  the  wire
connectors are firmly attached and that there is no exposed copper except
for the GROUND wire. 
7.  Gently  place  Budderfly  Controllable  Outlet  into  the  junction  box.  Then,
screw the Outlet into place. 
8.  Reinstall the wall plate 
9.  Enable power to the Outlet from the circuit breaker or fuse panel 
10. Add the device address to the Budderfly software. 
WARNING: If you are not sure about any part of the above instructions, 
consult a qualified electrician. 
WARNING –ELECTRICAL SHOCK HAZARD 
• 
The  Budderfly  Controllable  Outlet  is  intended  for  installation  in  accordance  with  the 
National Electric Code and local regulations in the United States. 
• 
If you are not knowledgeable or comfortable with electrical circuitry, you should have a 
qualified electrician install the Budderfly Controllable Outlet for you.
 
 Warning 
• 
Install the Budderfly Controllable Outlets indoor only. 
• 
Never use the Budderfly Outlets to power medical and/or life support equipment. 
WARNING –ELECTRICAL SHOCK HAZARD 
• 
Turn OFF the power to the branch circuit for the Outlet at the 
service panel. 
• 
All wiring connections must be made with the POWER OFF to 
avoid personal injury and/or damage to the Outlet. 
Wiring Information 
• 
Important:  Budderfly  Controllable  Outlet  is  rated  for  and 
intended to only be used with copper wire. 
• 
Use 12 AWG or larger wires suitable for 80
o.
 
• 
Remove 3/4" (1.9 cm) of insulation from each wire. 
Connect  as  follows:  Twist  strands  of  each  end  tightly  together.  Hold 
bare ends of wires together and push firmly into wire Nut. Screw Nut 
clockwise  making  sure  that  no  bare  conductor  shows  below  the 
connector