Modes of operation 
November 2007 
Revision 1.0 
25/45 
 
•  In slave mode, user commands and data exchanges are transmitted through this port. It 
can be set to RS-232, RS-485 or RS-422 mode by software. Different baudrates are 
available to each mode. 
Refer to
 Serial Port Pin Assignment
 for more details about cabling serial links.  
Tx (Transmit Data) and Rx (Receive Data) LEDs indicate the activity of the serial port. 
4.5.2  Monitoring Port (Parallel Port) 
This port (connector on the RFID reader inside the electrical cabinet) is dedicated to monitoring the 
reader. (Not to be used with customer application) 
The monitoring port communicates directly with the DSP firmware stored in the Flash memory. 
When the parallel cable is plugged in, the GemCore
®
 OS and STX application software is 
automatically deselected. The parallel port can be used as a monitoring tool or as a means to set 
up or debug the CONVEYOR TUNNEL READER via the L200 Explorer. 
4.5.3  Ethernet Port on the PLC Controller 
 
This port is devoted to external monitoring of the PLC, for customized conveyor command or I/O 
management. 
The RJ45 connector is on the WAGO PLC, inside the electrical cabinet of the Conveyor Tunnel 
Reader. 
4.5.4 Main Power Supply 
A
 
3-pole shielded cable of section >=3G2,5² must be connected by a sworn electrician directly on 
the electrical terminals N°1, 2, and 3 inside the electrical cabinet.  
Yellow / green terminal refer to the ground cable.  
Conveyor Tunnel Reader power consumption less than 500W. 
 
The RS-232 cable is a null modem cable. 
 
The parallel cable uses pin-to-pin DB25 connectors. A shielded cable must be used to prevent 
disruptions when antennas have a high output power. 
 
CAUTION
: 2 versions of Conveyor Tunnel Reader are available: 230VAC/50Hz and 
                  110VAC/60Hz power supply. 
Therefore check carefully the version before connecting the power cable.