4.1.2  Electrical Safety Rules 
The  mains  powers  the  L-SP2  so  it  is  necessary  to  provide  a  differential  protection  and  a 
shutting-off device.  
Figure 3
 below shows how to connect the L-SP2 pedestals to the mains. 
 
Figure 3: Safety Electrical Installation 
 
 
 
Micro 
 
circuit
 
breaker
 
Differential
 
circuit
 
-
 
breaker
 
AC main line 
Neutral
 
AC main
 
L-SP2
 
L-SP2
 
L-SP2
 
 
The power supply cable provided is of PVC type, H05VVF 0.75 mm² multi-stranded (14 AWG) and 
complies with FEC60950 standard. 
 
4.1.3  Network cable installation 
The  LSP2  Ethernet  version  is  provided  with  an  Ethernet  cable  mounted  with  a  ferrite  for  LAN 
cables. If the cable is to be changed, you will have to add a ferrite to this cable.  
References: 
•  Ethernet cable: Unshielded Ethernet cable, UTP-Cat5  
•  Ferrite for LAN cable: Würth Electronik (Manufacturer ref: 742 7111) 
 
This ferrite will have to be installed as follow (Figure 4):  
•  Inside the electronic casing 
•  Near the Moxa board 
•  20mm maximum distance from the RJ45 connector. 
 
The electrical installation must be carried on by qualified personnel only. Micro circuit breaker 
and differential circuit-breaker ratings depend on country regulations in force.