Tagsys S.A. LIBPEDESTALAFI 用户手册
Installation
July 2008
Revision 4.2
21/62
4.3.2 Placement of Pedestals
Pedestals must be mounted between 800 and 915 mm apart (edge to edge) for maximum
reliable performance. There should be at least one pair of pedestals at each entrance/exit point of
the library. There should be a pedestal at each edge of the entrance, and a clear space of at least
500 mm around the edge of the pedestals to ensure that the antennas will not be detuned. This
clear space must not contain any metallic objects, but may contain some substrates such as non-
metallic/non-conductive building materials such as wood, glass, chipboards and plasterboards.
the library. There should be a pedestal at each edge of the entrance, and a clear space of at least
500 mm around the edge of the pedestals to ensure that the antennas will not be detuned. This
clear space must not contain any metallic objects, but may contain some substrates such as non-
metallic/non-conductive building materials such as wood, glass, chipboards and plasterboards.
Be cautious to properly align the pedestal in order to centre the photoelectric beam sensor on the
reflector of the next pedestal.
reflector of the next pedestal.
Figure 5: Clearance around Pedestal
A
: Indicates the distance (6 ft.
6in.) to a permanent librarian
position.
position.
B
: Indicates the distance (8 ft.)
from other RFID stations.
C
: Indicates the recommended
distance (36 in. face panel to
face
face
panel)
between
pedestals.
D
: Indicates
the
minimum
distance (31½ in.) between a
pedestal and large metal
object.
pedestal and large metal
object.
E
: Indicates
the
minimum
distance (20 in.) between a
pedestal and small metal
object.
pedestal and small metal
object.
F
: Indicates
the
minimum
distance (30 ft.) between
Master
Master
pedestals
(specific
synchronization
ID,
see
section 5.2 “Understanding
the L-SP2 Synchronization
Process”).
the L-SP2 Synchronization
Process”).
CAUTION:
In case several pedestal row to be installed it is recommended every L-SP2 gate
being positioned in the same direction (the people counter of each looking toward the same
direction)
direction)
CAUTION:
Each L-SP2 should be installed within following tolerances:
Horizontal angular alignment tolerance with reference to pedestals alignment: 0° +/-2°
Vertical angular tolerance with reference to ground surface : 90° +/-1°
Vertical angular tolerance with reference to ground surface : 90° +/-1°
C
36 in.
(91.4 cm)
(91.4 cm)
A
6 ft. 6 in. (2 m)
F
30 ft. (9.1 m)
B
8 ft. (2.4 m)
D
31½ in. (80 cm)
E
20 in. (50 cm)
20 in. (50 cm)